{"title":"Regulator","description":"\u003ch1 data-section-id=\"1nbsvs5\" data-start=\"163\" data-end=\"248\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"165\" data-end=\"248\"\u003eWhat is a Gas Regulator? The Importance of Pressure Control in Industrial Burner Systems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"250\" data-end=\"688\"\u003eGas regulators are one of the most critical safety and performance components in industrial gas and burner systems. Gas regulators control the high-pressure gas in the system and ensure it is delivered to the burner at a suitable and constant pressure. This ensures both safe combustion and maintains system efficiency. \u003cstrong data-start=\"558\" data-end=\"571\"\u003eUK Teknik\u003c\/strong\u003e provides gas regulator supply, technical service, and maintenance services for industrial furnace and burner systems.\u003c\/p\u003e\n\u003chr data-start=\"690\" data-end=\"693\"\u003e\n\u003ch2 data-section-id=\"1qu869r\" data-start=\"695\" data-end=\"723\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"698\" data-end=\"723\"\u003eWhat is a Gas Regulator?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"725\" data-end=\"852\"\u003eA gas regulator is a device that reduces the high and variable gas pressure at its inlet to provide a constant and controlled pressure at its outlet.\u003c\/p\u003e\n\u003cp data-start=\"854\" data-end=\"870\"\u003eIts main functions are:\u003c\/p\u003e\n\u003cul data-start=\"871\" data-end=\"1012\"\u003e\n\u003cli data-section-id=\"1kp7sq9\" data-start=\"871\" data-end=\"899\"\u003eStabilizing gas pressure\u003c\/li\u003e\n\u003cli data-section-id=\"14jk4vg\" data-start=\"900\" data-end=\"943\"\u003eProviding suitable pressure for burner systems\u003c\/li\u003e\n\u003cli data-section-id=\"18f8dug\" data-start=\"944\" data-end=\"979\"\u003eCreating a safe combustion environment\u003c\/li\u003e\n\u003cli data-section-id=\"4acye5\" data-start=\"980\" data-end=\"1012\"\u003eProtecting system equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1014\" data-end=\"1064\"\u003eWithout a regulator, gas systems cannot operate stably.\u003c\/p\u003e\n\u003chr data-start=\"1066\" data-end=\"1069\"\u003e\n\u003ch2 data-section-id=\"fdayrx\" data-start=\"1071\" data-end=\"1107\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1074\" data-end=\"1107\"\u003eHow Does a Gas Regulator Work?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1109\" data-end=\"1210\"\u003eGas regulators automatically balance pressure through a diaphragm and spring system within their internal structure.\u003c\/p\u003e\n\u003cp data-start=\"1212\" data-end=\"1227\"\u003eOperation process:\u003c\/p\u003e\n\u003col data-start=\"1228\" data-end=\"1358\"\u003e\n\u003cli data-section-id=\"19bgmai\" data-start=\"1228\" data-end=\"1265\"\u003eHigh-pressure gas enters\u003c\/li\u003e\n\u003cli data-section-id=\"cxa07h\" data-start=\"1266\" data-end=\"1295\"\u003eDiaphragm senses pressure\u003c\/li\u003e\n\u003cli data-section-id=\"8f17x6\" data-start=\"1296\" data-end=\"1325\"\u003eSpring system provides balance\u003c\/li\u003e\n\u003cli data-section-id=\"hat88i\" data-start=\"1326\" data-end=\"1358\"\u003eConstant pressure is created at the outlet\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"1360\" data-end=\"1424\"\u003eThis mechanism ensures that burner systems operate safely.\u003c\/p\u003e\n\u003chr data-start=\"1426\" data-end=\"1429\"\u003e\n\u003ch2 data-section-id=\"126v7ed\" data-start=\"1431\" data-end=\"1470\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1434\" data-end=\"1470\"\u003eApplications of Gas Regulators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1472\" data-end=\"1527\"\u003eGas regulators are used in many industrial areas:\u003c\/p\u003e\n\u003cul data-start=\"1529\" data-end=\"1700\"\u003e\n\u003cli data-section-id=\"1y26r82\" data-start=\"1529\" data-end=\"1553\"\u003eIndustrial furnaces\u003c\/li\u003e\n\u003cli data-section-id=\"gz9201\" data-start=\"1554\" data-end=\"1584\"\u003eBurner and combustion systems\u003c\/li\u003e\n\u003cli data-section-id=\"syy6bb\" data-start=\"1585\" data-end=\"1609\"\u003eHeat treatment facilities\u003c\/li\u003e\n\u003cli data-section-id=\"zyyxy4\" data-start=\"1610\" data-end=\"1630\"\u003ePremix burners\u003c\/li\u003e\n\u003cli data-section-id=\"bvn9gb\" data-start=\"1631\" data-end=\"1663\"\u003eDrying and baking ovens\u003c\/li\u003e\n\u003cli data-section-id=\"19iixaz\" data-start=\"1664\" data-end=\"1700\"\u003eGas lines and process systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1702\" data-end=\"1748\"\u003eCorrect pressure control is the foundation of the entire system.\u003c\/p\u003e\n\u003chr data-start=\"1750\" data-end=\"1753\"\u003e\n\u003ch2 data-section-id=\"1l9wlss\" data-start=\"1755\" data-end=\"1784\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1758\" data-end=\"1784\"\u003eTypes of Gas Regulators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1786\" data-end=\"1841\"\u003eDifferent types of regulators are available depending on the application.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zoj4l9\" data-start=\"1843\" data-end=\"1877\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1847\" data-end=\"1877\"\u003eLow Pressure Regulators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1878\" data-end=\"1930\"\u003e\n\u003cli data-section-id=\"16ea5fq\" data-start=\"1878\" data-end=\"1930\"\u003eUsed in systems requiring precise control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19y2ibi\" data-start=\"1932\" data-end=\"1967\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1936\" data-end=\"1967\"\u003eHigh Pressure Regulators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1968\" data-end=\"2012\"\u003e\n\u003cli data-section-id=\"1puohil\" data-start=\"1968\" data-end=\"2012\"\u003ePreferred for industrial gas lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"tc39ul\" data-start=\"2014\" data-end=\"2050\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2018\" data-end=\"2050\"\u003ePilot Operated Regulators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2051\" data-end=\"2099\"\u003e\n\u003cli data-section-id=\"ya356s\" data-start=\"2051\" data-end=\"2099\"\u003eProvide more stable and precise pressure control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1gdy8ma\" data-start=\"2101\" data-end=\"2137\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2105\" data-end=\"2137\"\u003eDirect Acting Regulators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2138\" data-end=\"2181\"\u003e\n\u003cli data-section-id=\"1l04cy8\" data-start=\"2138\" data-end=\"2181\"\u003eSimple systems with fast response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2183\" data-end=\"2186\"\u003e\n\u003ch2 data-section-id=\"19zrf1r\" data-start=\"2188\" data-end=\"2234\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2191\" data-end=\"2234\"\u003eGas Regulator Faults and Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2236\" data-end=\"2303\"\u003eVarious problems can occur over time or due to improper use.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v2q1ho\" data-start=\"2305\" data-end=\"2332\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2309\" data-end=\"2332\"\u003ePressure Fluctuations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2333\" data-end=\"2389\"\u003e\n\u003cli data-section-id=\"vnib2i\" data-start=\"2333\" data-end=\"2362\"\u003eCombustion becomes unstable\u003c\/li\u003e\n\u003cli data-section-id=\"1h7yu0e\" data-start=\"2363\" data-end=\"2389\"\u003eSystem does not operate stably\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"ycfh14\" data-start=\"2391\" data-end=\"2409\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2395\" data-end=\"2409\"\u003eGas Leakage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2410\" data-end=\"2449\"\u003e\n\u003cli data-section-id=\"1oiiv5r\" data-start=\"2410\" data-end=\"2449\"\u003eGasket or diaphragm damage may occur\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"6mhn3f\" data-start=\"2451\" data-end=\"2482\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2455\" data-end=\"2482\"\u003eLow Outlet Pressure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2483\" data-end=\"2520\"\u003e\n\u003cli data-section-id=\"2lhmn\" data-start=\"2483\" data-end=\"2520\"\u003eInsufficient combustion performance occurs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1xpjhvw\" data-start=\"2522\" data-end=\"2546\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2526\" data-end=\"2546\"\u003eLoss of Regulation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2547\" data-end=\"2579\"\u003e\n\u003cli data-section-id=\"3a045u\" data-start=\"2547\" data-end=\"2579\"\u003eSystem becomes uncontrollable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2581\" data-end=\"2631\"\u003eThese situations directly affect production efficiency.\u003c\/p\u003e\n\u003chr data-start=\"2633\" data-end=\"2636\"\u003e\n\u003ch2 data-section-id=\"f1r6qh\" data-start=\"2638\" data-end=\"2675\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2641\" data-end=\"2675\"\u003eImportance of Gas Regulator Maintenance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2677\" data-end=\"2706\"\u003eWithout regular maintenance:\u003c\/p\u003e\n\u003cul data-start=\"2707\" data-end=\"2785\"\u003e\n\u003cli data-section-id=\"12we5sq\" data-start=\"2707\" data-end=\"2734\"\u003ePressure control deteriorates\u003c\/li\u003e\n\u003cli data-section-id=\"1hw2vhg\" data-start=\"2735\" data-end=\"2760\"\u003eSafety risk arises\u003c\/li\u003e\n\u003cli data-section-id=\"1oqczw5\" data-start=\"2761\" data-end=\"2785\"\u003eFuel consumption increases\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2787\" data-end=\"2805\"\u003eWith regular maintenance:\u003c\/p\u003e\n\u003cul data-start=\"2806\" data-end=\"2877\"\u003e\n\u003cli data-section-id=\"mmr72k\" data-start=\"2806\" data-end=\"2833\"\u003eStable operation is ensured\u003c\/li\u003e\n\u003cli data-section-id=\"ojp0no\" data-start=\"2834\" data-end=\"2854\"\u003eSystem lifespan is extended\u003c\/li\u003e\n\u003cli data-section-id=\"13uagcu\" data-start=\"2855\" data-end=\"2877\"\u003eRisk of failure is reduced\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2879\" data-end=\"2898\"\u003eDuring maintenance:\u003c\/p\u003e\n\u003cul data-start=\"2899\" data-end=\"2986\"\u003e\n\u003cli data-section-id=\"1lbagyn\" data-start=\"2899\" data-end=\"2915\"\u003ePressure test\u003c\/li\u003e\n\u003cli data-section-id=\"1nrqaye\" data-start=\"2916\" data-end=\"2937\"\u003eDiaphragm check\u003c\/li\u003e\n\u003cli data-section-id=\"1g5suss\" data-start=\"2938\" data-end=\"2957\"\u003eGas leak test\u003c\/li\u003e\n\u003cli data-section-id=\"19rqpnv\" data-start=\"2958\" data-end=\"2986\"\u003eSpring mechanism check\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2988\" data-end=\"3009\"\u003emust be performed.\u003c\/p\u003e\n\u003chr data-start=\"3011\" data-end=\"3014\"\u003e\n\u003ch2 data-section-id=\"1jr2y5j\" data-start=\"3016\" data-end=\"3074\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3019\" data-end=\"3074\"\u003ePoints to Consider When Choosing a Gas Regulator\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3076\" data-end=\"3139\"\u003eCorrect selection is critically important for system performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iupacf\" data-start=\"3141\" data-end=\"3163\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3145\" data-end=\"3163\"\u003eGas Type Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3164\" data-end=\"3207\"\u003e\n\u003cli data-section-id=\"caod4d\" data-start=\"3164\" data-end=\"3176\"\u003eNatural gas\u003c\/li\u003e\n\u003cli data-section-id=\"16s5b77\" data-start=\"3177\" data-end=\"3184\"\u003eLPG\u003c\/li\u003e\n\u003cli data-section-id=\"1i1rmwk\" data-start=\"3185\" data-end=\"3207\"\u003eIndustrial gases\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"135q0hb\" data-start=\"3209\" data-end=\"3231\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3213\" data-end=\"3231\"\u003ePressure Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3232\" data-end=\"3276\"\u003e\n\u003cli data-section-id=\"1qla6n3\" data-start=\"3232\" data-end=\"3276\"\u003eInlet and outlet values must be correct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"zdend2\" data-start=\"3278\" data-end=\"3301\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3282\" data-end=\"3301\"\u003eFlow Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3302\" data-end=\"3339\"\u003e\n\u003cli data-section-id=\"zow1r5\" data-start=\"3302\" data-end=\"3339\"\u003eMust be suitable for system requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1d8eu1i\" data-start=\"3341\" data-end=\"3368\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3345\" data-end=\"3368\"\u003eIndustrial Durability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3369\" data-end=\"3415\"\u003e\n\u003cli data-section-id=\"1qzhdy5\" data-start=\"3369\" data-end=\"3415\"\u003eMust be suitable for high temperature and pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3417\" data-end=\"3420\"\u003e\n\u003ch2 data-section-id=\"10yscpg\" data-start=\"3422\" data-end=\"3463\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3425\" data-end=\"3463\"\u003eUK Teknik Gas Regulator Solutions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3465\" data-end=\"3506\"\u003e\u003cstrong data-start=\"3465\" data-end=\"3478\"\u003eUK Teknik\u003c\/strong\u003e offers for industrial facilities:\u003c\/p\u003e\n\u003cul data-start=\"3508\" data-end=\"3612\"\u003e\n\u003cli data-section-id=\"1s7sam8\" data-start=\"3508\" data-end=\"3535\"\u003eGas regulator supply\u003c\/li\u003e\n\u003cli data-section-id=\"13s9lld\" data-start=\"3536\" data-end=\"3562\"\u003eTechnical service and maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"15an5rq\" data-start=\"3563\" data-end=\"3594\"\u003ePressure system optimization\u003c\/li\u003e\n\u003cli data-section-id=\"1o8yhsn\" data-start=\"3595\" data-end=\"3612\"\u003eTroubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3614\" data-end=\"3637\"\u003eservices.\u003c\/p\u003e\n\u003cp data-start=\"3639\" data-end=\"3700\"\u003eSafe and efficient production is ensured with correct pressure control.\u003c\/p\u003e\n\u003chr data-start=\"3702\" data-end=\"3705\"\u003e\n\u003ch2 data-section-id=\"9utnno\" data-start=\"3707\" data-end=\"3749\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3710\" data-end=\"3749\"\u003eWhy Work with UK Teknik?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3751\" data-end=\"3828\"\u003eGas regulators are critical equipment at the heart of burner systems.\u003c\/p\u003e\n\u003cp data-start=\"3830\" data-end=\"3844\"\u003e\u003cstrong data-start=\"3830\" data-end=\"3844\"\u003eUK Teknik:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3845\" data-end=\"3957\"\u003e\n\u003cli data-section-id=\"1n3lm17\" data-start=\"3845\" data-end=\"3881\"\u003eIndustrial engineering experience\u003c\/li\u003e\n\u003cli data-section-id=\"8p8sy0\" data-start=\"3882\" data-end=\"3905\"\u003eFast technical service\u003c\/li\u003e\n\u003cli data-section-id=\"huqh01\" data-start=\"3906\" data-end=\"3931\"\u003eCompatible product solutions\u003c\/li\u003e\n\u003cli data-section-id=\"18cm9t\" data-start=\"3932\" data-end=\"3957\"\u003eOn-site maintenance support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3959\" data-end=\"4007\"\u003eprovides a safe production infrastructure for businesses.\u003c\/p\u003e","products":[{"product_id":"novacomet-bp-2303r-30kgh-lpg-regulator","title":"Novacomet BP-2303R 30 kg\/h LPG Pressure Reducing Regulator 3\/4” - 1\/2” | UK Teknik","description":"\u003ch1 data-section-id=\"1elc39r\" data-start=\"133\" data-end=\"191\"\u003eNovacomet BP-2303R 30 kg\/h LPG Pressure Reducing Regulator\u003c\/h1\u003e\n\u003cp data-start=\"193\" data-602\"\u003eThe \u003cstrong data-start=\"280\" data-end=\"324\"\u003eNovacomet BP-2303R 30 kg\/h LPG regulator\u003c\/strong\u003e, which provides safe, stable, and precise gas pressure control in industrial LPG systems, has been developed for professional use with its high flow capacity and durable structure. It offers reliable operating performance by ensuring a stable gas flow, especially in industrial LPG lines, central gas systems, industrial stoves, burner systems, and process applications.\u003c\/p\u003e\n\u003cp data-start=\"604\" data-end=\"823\"\u003eThis high-performance LPG pressure-reducing regulator model, offered by \u003cstrong data-start=\"604\" data-end=\"641\"\u003eUK Teknik Industrial Consulting\u003c\/strong\u003e, provides long-lasting use and high safety advantages thanks to its compliance with European standards.\u003c\/p\u003e\n\u003ch2 data-section-id=\"lffr2b\" data-start=\"825\" data-end=\"845\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3 data-section-id=\"og5pwi\" data-start=\"847\" data-end=\"866\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cul data-start=\"867\" data-end=\"1218\"\u003e\n\u003cli data-section-id=\"1hke9yq\" data-start=\"867\" data-end=\"884\"\u003eModel: BP-2303R\u003c\/li\u003e\n\u003cli data-section-id=\"vj8isg\" data-start=\"885\" data-end=\"903\"\u003eBrand: Novacomet\u003c\/li\u003e\n\u003cli data-section-id=\"h0qcde\" data-start=\"904\" data-end=\"946\"\u003eProduct Type: LPG Pressure Reducing Regulator\u003c\/li\u003e\n\u003cli data-section-id=\"nh6wlt\" data-start=\"947\" data-end=\"971\"\u003eInlet Connection: 1\/2”\u003c\/li\u003e\n\u003cli data-section-id=\"1gybs30\" data-start=\"972\" data-end=\"996\"\u003eOutlet Connection: 3\/4”\u003c\/li\u003e\n\u003cli data-section-id=\"rjdmt4\" data-start=\"997\" data-end=\"1025\"\u003eInlet Pressure: 0.5 – 4 Bar\u003c\/li\u003e\n\u003cli data-section-id=\"6fcilf\" data-start=\"1026\" data-end=\"1050\"\u003eOutlet Pressure: 30 mbar\u003c\/li\u003e\n\u003cli data-section-id=\"2myawa\" data-start=\"1051\" data-end=\"1070\"\u003eCapacity: 30 kg\/h\u003c\/li\u003e\n\u003cli data-section-id=\"39592i\" data-start=\"1071\" data-end=\"1108\"\u003eOperating Temperature: -20 °C \/ +60 °C\u003c\/li\u003e\n\u003cli data-section-id=\"37n3kh\" data-start=\"1109\" data-end=\"1124\"\u003eGas Type: LPG\u003c\/li\u003e\n\u003cli data-section-id=\"59hhvj\" data-start=\"1125\" data-end=\"1173\"\u003eBody Structure: Corrosion-resistant metal alloy\u003c\/li\u003e\n\u003cli data-section-id=\"22vkj3\" data-start=\"1174\" data-end=\"1218\"\u003eArea of Use: Industrial LPG systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1iv1ud0\" data-start=\"1220\" data-end=\"1263\"\u003eAdvantages of Novacomet BP-2303R Regulator\u003c\/h2\u003e\n\u003ch3 data-section-id=\"qfob9i\" data-start=\"1265\" data-end=\"1287\"\u003eStable Gas Pressure\u003c\/h3\u003e\n\u003cp data-start=\"1288\" data-end=\"1397\"\u003eEnsures balanced gas flow in the LPG line with a constant 30 mbar outlet pressure, increasing system efficiency.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1kf0fed\" data-start=\"1399\" data-end=\"1425\"\u003eHigh Flow Capacity\u003c\/h3\u003e\n\u003cp data-start=\"1426\" data-end=\"1538\"\u003eWith a capacity of 30 kg\/h, it offers uninterrupted operating performance in industrial applications requiring high consumption.\u003c\/p\u003e\n\u003ch3 data-section-id=\"cmhqb5\" data-start=\"1540\" data-end=\"1567\"\u003eSafe Operating System\u003c\/h3\u003e\n\u003cp data-start=\"1568\" data-end=\"1685\"\u003eProvides safe use in LPG systems thanks to its advanced safety mechanism against pressure fluctuations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ydp9qs\" data-start=\"1687\" data-end=\"1717\"\u003eDurable Industrial Structure\u003c\/h3\u003e\n\u003cp data-start=\"1718\" data-end=\"1825\"\u003eOffers long-lasting use in demanding operating environments thanks to its corrosion-resistant metal body.\u003c\/p\u003e\n\u003ch2 data-section-id=\"dehkys\" data-start=\"1827\" data-end=\"1847\"\u003eAreas of Use\u003c\/h2\u003e\n\u003cp data-start=\"1849\" data-end=\"1947\"\u003eThe Novacomet BP-2303R LPG regulator model is commonly preferred in the following applications:\u003c\/p\u003e\n\u003cul data-start=\"1949\" data-end=\"2179\"\u003e\n\u003cli data-section-id=\"r8yydb\" data-start=\"1949\" data-end=\"1974\"\u003eIndustrial LPG lines\u003c\/li\u003e\n\u003cli data-section-id=\"17iuosz\" data-start=\"1975\" data-end=\"1999\"\u003eCentral LPG systems\u003c\/li\u003e\n\u003cli data-section-id=\"b620tz\" data-start=\"2000\" data-end=\"2023\"\u003eGas burner systems\u003c\/li\u003e\n\u003cli data-section-id=\"3q3h9o\" data-start=\"2024\" data-end=\"2056\"\u003eIndustrial kitchen equipment\u003c\/li\u003e\n\u003cli data-section-id=\"gz6y15\" data-start=\"2057\" data-end=\"2095\"\u003eIndustrial stove and oven systems\u003c\/li\u003e\n\u003cli data-section-id=\"1gguqsc\" data-start=\"2096\" data-end=\"2115\"\u003eHeating systems\u003c\/li\u003e\n\u003cli data-section-id=\"46iekl\" data-start=\"2116\" data-end=\"2149\"\u003eLPG pressure control applications\u003c\/li\u003e\n\u003cli data-section-id=\"1ptzo2w\" data-start=\"2150\" data-end=\"2179\"\u003eIndustrial gas installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"2xa94o\" data-start=\"2181\" data-end=\"2224\"\u003eWhy UK Teknik Industrial Consulting?\u003c\/h2\u003e\n\u003cp data-start=\"2226\" data-end=\"2536\"\u003e\u003cstrong data-start=\"2226\" data-end=\"2263\"\u003eUK Teknik Industrial Consulting\u003c\/strong\u003e provides reliable product supply and professional consulting services in industrial gas equipment and technical system solutions. It offers professional solutions in product selection, safe use, and technical support processes for industrial LPG regulator systems.\u003c\/p\u003e\n\u003cp data-start=\"2538\" data-end=\"2690\"\u003eYou can contact us for detailed information about high-performance Novacomet regulator solutions for your industrial LPG systems.\u003c\/p\u003e\n\u003cp data-start=\"2692\" data-end=\"2772\"\u003e📍 Gölcük \/ Kocaeli \/ Turkey\u003cbr data-start=\"2721\" data-end=\"2724\"\u003e📞 +90 (541) 120 60 99\u003cbr data-start=\"2746\" data-end=\"2749\"\u003e📧 \u003ca data-start=\"2752\" data-end=\"2772\" class=\"decorated-link cursor-pointer docs-creator\" rel=\"noopener\"\u003einfo@ukteknik.com.tr\u003c\/a\u003e\u003c\/p\u003e","brand":"UK TEKNİK","offers":[{"title":"Default Title","offer_id":46839288987804,"sku":null,"price":0.0,"currency_code":"TRY","in_stock":true}]}],"url":"https:\/\/www.ukteknik.com.tr\/en\/collections\/gaz-regulatoru-endustriyel-basinc-kontrol-sistemleri.oembed","provider":"UK TEKNİK","version":"1.0","type":"link"}